Mwrf 2241 Ni 0
Mwrf 2241 Ni 0
Mwrf 2241 Ni 0
Mwrf 2241 Ni 0
Mwrf 2241 Ni 0

Load-Pull Analysis with Software Enables Wave of Designs

April 8, 2016
An application note explains how design software can be used to perform load-pull analysis, thereby enhancing the design process.
Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

Load-pull analysis is an important aspect of the design process of an amplifier, as this technique is often used to determine an appropriate load. Thus, by utilizing load-pull techniques, amplifiers can be designed more efficiently. In the application note, "Load-Pull Analysis Using NI AWR Software," National Instruments presents three design examples that take advantage of the load-pull technique. These designs are aided with the NI AWR Design Environment.

The first example demonstrates a simple load-pull analysis. The impedances that were obtained are presented on the Smith Chart. Additional graphs display saved data sets of measured output power versus gain compression, output power versus power-added efficiency (PAE), and input power versus output power. By taking advantage of the capabilities of the NI AWR software, designers can quickly learn the impact of load/source terminations on an amplifier’s performance over swept input power. Power amplifier (PA) designers can therefore gain a better understanding of the tradeoffs between load impedance and gain compression behavior.

Courtesy of National Instruments

In the next example, a device was terminated in a matching network based on a microstrip transmission line transformer. The impedances that were obtained are once again displayed on the Smith Chart. Contour lines on the Smith Chart indicate where +45 dBm of output power and 70% PAE can be attained, respectively. The layout of the matching circuit is presented, as well as the performance characteristics of the device with the matching network.

The third example investigates circuit optimization by means of electromagnetic (EM) field analysis. By leveraging EM analysis, a more accurate representation of the matching network impedance can be achieved. Although EM analysis is often used in design verifications after the final design has been achieved, this example illustrates the accuracy of EM analysis when used earlier in the design process. The schematic and layout of the final project is presented. The output matching circuit for the transistor model was also created based on the measured load-pull file to investigate the current distribution through the matching structure.

National Instruments Corp., 11500 N Mopac Expwy., Austin, TX 78759-3504; (877) 388-1952

Looking for parts? Go to SourceESB.

Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

Sponsored Recommendations

Frequency Modulation Fundamentals

March 14, 2024
The development of crystal-clear FM communications was an innovation of genius and toil. Utilized today in applications such as radar, seismology, telemetry and two-way radios...

44 GHz Programmable Signal Generator

March 14, 2024
The Mini-Circuits SSG-44G-RC is a 0.1 to 44 GHz signal source with an RF output range of -40 to +17 dBm with fine resolution. This model supports CW and pulsed (? 0.5 ?s) outputs...

Webinar: Introduction to OTA Measurement for mmWave and Sub-THz

Feb. 19, 2024
Join Jeanmarc Laurent, a leading expert from MilliBox, for an exclusive live webinar showcasing a complete Over-the-Air (OTA) testing system setup. In this immersive session, ...

Using a CMT VNA with Socket Server

Feb. 19, 2024
This application note describes use of a software application CMT Socket Server which is distributed and supported by Aphena Ltd. Please email [email protected] regarding purchase...