Wearable System Monitors Heart Health

CARDIAC OUTPUT IS commonly monitored by methods like invasive intra-cardiac catheterization and non-invasive Doppler ultrasound anatomy. Yet catheter insertion invites both risk and side effects, while echocardiography requires equipment that is typically bulky and controlled by skilled operatorsthereby increasing cost. Such issues, coupled with advances in wireless communications, have prompted the use of wearable healthcare sensor systems. At the Korea Advanced Institute of Science and Technology, a low-power, sensitive, Thoracic Impedance Variance (TIV) and electrocardiogram (ECG) monitoring system-on-a-chip (SoC) has been developed by Long Yan, Joonsung Bae, Seulki Lee, Taehwan Roh, Kiseok Song, and Hoi-Jun Yoo.

The team implemented this SoC in a poultice-like plaster sensor. With the help of a balanced, sinusoidal current source with a quality factor above 30 and low-noise, reconfigurable readout electronics, they found 0.1-Ω TIV detection to be possible with sensitivity of 3.17 V/O and a signal-to-noise ratio beyond 40 dB. To remotely start and stop the SoC, they used centimeter-range 13.56- MHz fabric inductor coupling. In order to achieve 0.2 nJ/b, 1-Mb/s energy-efficient external data communications, they relied on 5% duty-cycled body-channel communication.

This SoC comprises five functional blocks: a system startup module; four reconfigurable electrode-sensor front ends; a differential sinusoidal current generator; a digital module; and a duty-cycled body-channel transceiver. The SoC forms a compact, wearable sensor because it is integrated on a fabric circuit board along with a flexible battery. A total of 25 adhesive, screen-printed fabric electrodes allow TIV and ECG detection at 16 different sites around the heart. The base station can be located in any position on the body. In body-channel receiver mode, the CMOS-based SoC dissipates peak power of 3.9 mW. It consumes 2.4 mW when operating in TIV and ECG detection mode. See "A 3.9 mW 25- Electrode Reconfigured Sensor for Wearable Cardiac Monitoring System," IEEE Journal Of Solid-State Circuits, Jan. 2011, p. 353.

Please or Register to post comments.

Newsletter Signup

Webcasts

GaN Roundtable: The State of GaN Reliability Today

Wednesday, April 3rd, 2013, 2:00 pm ET. Gallium nitride (GaN) has come a long way over the past few years in terms of affordability, industry acceptance and, in particular, reliability. In this webcast roundtable, a panel of expert speakers will assess the current state of GaN reliability, along with offering predictions for its future.

Click here to register!

Whitepapers

New App Note: Best Practices for Making the Most Accurate Radar Pulse Measurements
Sponsored by Agilent Technologies
Download this app note

Agilent Technologies Complex Modulation Generation with Low Cost Arbitrary Waveform Generators - Agilent's Trueform Architecture for Wireless Applications
Sponsored by Agilent Technologies
Download this white paper

Browse more white papers from Microwaves and RF

Connect With Us